RVR-52
|
|
Measurement Channel
|
1Voltage Channel
1Pulse Channel
1Event Channel
|
|
Internal Temp. Sensor
|
-
|
|
External Temp. Sensor
|
-
|
|
External Humidity Sensor
|
-
|
|
Input Voltage Range
|
Vo: 0 to 6.5V
Pu: 0 to 30V
Ev: 0 to 30V
|
|
Measurement Display Resolution
|
Vo: 1mV
Ev: 1sec
|
|
Measurement Accuracy
|
±0.5%+5dgt (at 0 to 40)
|
|
Detection Voltage
|
Lo: below 0.6V / Hi: above 2V
|
|
Response Time
|
Pu:30Hz / Approx.15msec or more (over 2.5V) Ev: 1 sec.
|
|
Response Polarity
|
Pu: select Lo-Hi or Hi-Lo
Ev: Both Lo -Hi and Hi-Lo
|
|
Highest No. of Counts
|
Pu: 32,000Counts
|
|
Input Impedance
|
Vo: Approx, 1M Pu, Ev: Pull-up Resistor Approx.100k
|
|
Recording Interval
|
1,2,5,10,15,20,30 seconds / 1,2,5,10,15,20,30,60 minutes
Total of 15 choices (Excluding Event data)
|
|
Recording Capacity
|
Vo.Pu./16,000 Readings x 1 Channel
Ev./ 8,000 Readings x 1 Channnel
|
|
Recording Mode
|
Endless (Overwrite oldest data when capacity is full) / One-time (Stop recording when capacity is full)
|
|
LCD Display Items
|
Current Readings / Recording Settings / Battery Life Warning /
Over Measurement Range Warning / Amount of Recorded Data
|
|
Power
|
Lithium Battery (LS14250(SAFT)) x 1 or AC Adaptor (sold separately) *1
|
|
Battery Life *2
|
Approximately 6 months
|
|
Wireless Method
|
ETSI EN 300-220
|
|
Transmission Distance
|
H62mm x W 47mm x D19mm (excluding protrusions / antenna length 20mm)
|
|
|
Wireless Communication (RTR-57C) / Optical Communication (RTR-57C, TR-57C, TR-50C)
|
|
|
When downloading data (Wireless) about 2,000 readings per minute
[Collection of a full unit of data= about 420 seconds (optical communication= about 160 seconds)]
|
|
|
IP64 (rated for use in daily life)
|
Standard Sensor / Input Cable
|
RVR-7101 (length: Approx. 1.5m) x 1
|
|
|
|
|
Battery life depends on measurement environment, recording interval and battery performance.
Battery life depends on measurement environment, recording interval and battery performance.
Water protection is rated as splashproof (IP64) when the sensor is connected. Not for continued immersion
|