AVS140-1TemperatureValidationDataLoggingKit
By MadgeTech Data LoggersOverview
21 CFR Part 11 ~ Autoclave validation kit including 1 temperature data logger, IFC400 interface, secure software package, validation documentation and carry case.
Rated for High °C
Deploy in environments up to 140 °C. To record temperature ,includes interface
ISO17025 Calibration
Tested, calibrated and supplied with certificate
Validated
21 CFR Part 11 compliance and GxP documentation included
Information
Product Description
The AVS140-1 delivers unbeatable value to companies required to validate a process or appliance operating between -40°C ~ +140°C within an FDA regulated environment.
Kit contains;
1 x MadgeTech Secure Software 21 CFR Part 11 compliant software for configuring, downloading, analysis and reporting on data collected by any number of HiTemp140 data loggers.
1 x SVP Validation folder GxP documentation to aid operators in validating the software and hardware within a regulated environment.
1 x HiTemp140 Data logger with integral 1" probe, manufactured from stainless steel suitable for operation in an autoclave, accuracy is verified by the supplied traceable calibration certificate.
1 x IFC400 USB Docking Station, used to interface the HiTemp140 with a
1 x Carry case, houses all items supplied within the kit
Applications;
Primarily used to record temperature data to validate bench top sterliser autoclaves, delivering time temperature data and lethality values in a report format. But can also be used to accurately record ambient and product temperatures of items passed through freezers, fridges, ambient storage areas and incubators.with reports including time above or below user definable thresholds, standard deviation, MKT and maths channels where data is taken from multiple data loggers, averaged and plotted on a graph.
Specifications
- Manufacturer
Madgetech
- Parameter(s)
Temperature
- Usage Type
Multi use
- Connectivity
USB via IFC400
- Sensor internal or external
Temperature : External
- Channels
1 Temperature
- Sensor type
See specification sheet
- Memory
32,700 points
- Sample rate
every second ~reading every 24 hours
- Range
See specification sheet
- Accuracy
See specification sheet
- Resolution
See specification sheet
- Material
Stainless steel
- Power
Battery 3.6v lithium high temperature rated
- Battery Life
1 year typical
- Dimensions
See specification sheet
- Environment
IP68
- Operating Conditions
See specification sheet
- Features
rugged, high temperature, 21 CFR 11