AVS140-6AutoclaveValidationDataLoggingSystem
By MadgeTech Data LoggersOverview
21 CFR Part 11 ~ Autoclave validation kit including 5 temperature data loggers and 1 pressure data logger along with multiplexer IFC406 interface, secure software package, validation documentation and carry case.
Rated for High °C
Deploy in environments up to 140 °C. To record temperature at 5 points and pressure at 1 point includes case and interface
ISO17025 Calibration
Tested, calibrated and supplied with certificate
Validated
21 CFR Part 11 compliance and GxP documentation included
Information
Product Description
The AVS140-6 is a kit containing all the components to validate a small/medium sized Autoclave housed in handy carry case. As well as the hardware to perform the validation, included are calibration certificates and 21 CFR 11 compliant software with a validation workbook (IQ/OQ/PQ).
The PR140 pressure data logger and the temperature only HiTemp140 are IP68 fully submersible and are specifically designed for autoclave and steriliser validation. Each data logger has 32,000 memory points and a solid state memory, enabling data to be recovered in the event of power loss.
Madgetech HiTemp140 and PR140 are the most cost effective autoclave validation data loggers on the market and come packed with useful features.
Included in the system:
5 x HiTemp140 High Temperature Data Loggers with 1 in probe style, all with NIST Calibration Certificates
1 x PR140 Pressure Data Logger, with NIST Calibration Certificate
1 x IFC406 Multiplexer interface for programming 6 data loggers simultaneously
1 x MadgeTech Secure Data Logger Software, complete with IQ/OQ/PQ validation protocols and workbook
1 x Carry case with laser cut inserts for data loggers and accessories
Specifications
- Manufacturer
Madgetech
- Parameter(s)
Temperature and Pressure
- Usage Type
Multi use
- Connectivity
USB via IFC406
- Sensor internal or external
Temperature : External
Pressure : Internal- Channels
5 Temperature
1 Pressure- Sensor type
See specification sheet
- Memory
32,700 points per data logger
- Sample rate
every second ~reading every 24 hours
- Range
See specification sheet
- Accuracy
See specification sheet
- Resolution
See specification sheet
- Material
Stainless steel
- Power
Battery 3.6v lithium high temperature rated
- Battery Life
1 year typical
- Dimensions
See specification sheet
- Environment
IP68
- Operating Conditions
See specification sheet
- Features
rugged, high temperature and pressure, 21 CFR 11