Voltage wireless datalogger
product-RTR-505V
Voltage wireless datalogger
RTR-505-V

RTR-505-V Voltage Wireless Data Logger with External Adapter

From: £160.00

Voltage wireless TandD data logger for recording voltages between 0 ~ 22V.

Product Description

RTR-500 Series:  Wireless radio data logger from TandD including LCD display, supplied with a VIM-3010 adapter used to connect the RTR-505-V to an analogue sensor delivering 0 ~ 22v.

The RTR-505-V opens up the door to flexible RTR-500 system configurations, suitable for use in laboratories and research facilities.

By scaling the voltage output from an analogue sensor, the RTR-500 series can present you with a wide range of environmental data, using just one system.

  • CO2: Partner your RTR-505-V with the Vaisala GMT220, the market leading solution for permanent Carbon Dioxide in a Co2 incubator
  • Differential Pressure: Using a P sensor coupled with the voltage data logger will enable you to record pressure levels
  • O2: Oxygen depletion sensors can be used to measure and issue warnings or to perform trend analysis

Simply connect your analogue sensor to the RTR-505-V and monitor your environmental data using the designated base station, select from PC and/or on-line software utilities and monitor your data and alarm status of appliances and environments in real-time with archived data retained on your server and on-line with the free of charge with the TandD Webstorage-service.

Create a cost effective – local or global – scaleable network of data loggers with flexible access options via LAN/WLAN/USB and even 3G GSM. Ensuring your data can be reliably retrieved and actioned irrespective of existing I.T. infrastructure.

Supplied as standard with VIM -3010 voltage adapter and 3.6v user replaceable battery. Can be purchased with a [L] Long life battery upgrade or [PSU] external mains power adapter.

Free service: Provide our engineers with details of your monitoring requirements, we would be pleased to assist you in setting up your system ready for deployment.

RTR-500 Series Features

  • Remotely access your data over the internet for free.
  • Take control and ownership of your data using free issued offline analytical and archiving utilities.
  • Wide range of communication devices including the RTR500-DC handheld data collector for performing spot checks and analysis.
  • Robust and durable design.
  • Accurate and can be recalibrated.
  • User replaceable battery.
  • Optional GxP Validation service including installation.
  • Routine on-site calibration
Manufacturer

TandD

Parameter(s)

Voltage

Usage Type

Multiple Use

Connectivity

Wireless radio to USB [RTR-500]
Wireless radio to Ethernet LAN [RTR-500NW]
Wireless radio to Wireless LAN Wi-Fi [RTR-500AW]
Wireless radio to GSM 3G [RTR-500MBS]
Wireless radio to Handheld collector [RTR-500DC]

Sensor internal or external

External

Channels

1

Memory

16000 reading back-up memory

Sample rate

1 reading a second ~ 1 reading every hour

Range

0 ~ 22v

Accuracy

+/- 0.5mV
Contact our calibration department for advice on partnering with sensors and offset adjustment

Resolution

See specification sheet

Material

ABS Plastic with O-ring seal

Power

User replaceable battery
Mains with power supply adaptor

Battery Life

10 months - Standard battery
24 ~ 48 months - [L] Large battery

Dimensions

86mm x 47mm x 19mm - Standard battery
86mm x 47mm x 46.5mm - [L] Large battery

Environment

IP64 Splashproof
Sensor must be kept dry

Operating Conditions

-40°C ~ +80°C

Alarm

Email when using any RTR-500 base station
SMS text message when using RTR-500MBS
On-line when using TandD Webstorage-service
On PC when using Current readings utility
Audible/Visual beacon with optional attachment for base station

Features

Free remote internet access.
Free offline analytical and reporting utilities
Robust and durable design.
Accurate and can be recalibrated
User replaceable battery

Product Brochure
RTR500 Overview Brochure WPLSPDF40MB

Product Description

RTR-500 Series:  Wireless radio data logger from TandD including LCD display, supplied with a VIM-3010 adapter used to connect the RTR-505-V to an analogue sensor delivering 0 ~ 22v.

The RTR-505-V opens up the door to flexible RTR-500 system configurations, suitable for use in laboratories and research facilities.

By scaling the voltage output from an analogue sensor, the RTR-500 series can present you with a wide range of environmental data, using just one system.

  • CO2: Partner your RTR-505-V with the Vaisala GMT220, the market leading solution for permanent Carbon Dioxide in a Co2 incubator
  • Differential Pressure: Using a P sensor coupled with the voltage data logger will enable you to record pressure levels
  • O2: Oxygen depletion sensors can be used to measure and issue warnings or to perform trend analysis

Simply connect your analogue sensor to the RTR-505-V and monitor your environmental data using the designated base station, select from PC and/or on-line software utilities and monitor your data and alarm status of appliances and environments in real-time with archived data retained on your server and on-line with the free of charge with the TandD Webstorage-service.

Create a cost effective – local or global – scaleable network of data loggers with flexible access options via LAN/WLAN/USB and even 3G GSM. Ensuring your data can be reliably retrieved and actioned irrespective of existing I.T. infrastructure.

Supplied as standard with VIM -3010 voltage adapter and 3.6v user replaceable battery. Can be purchased with a [L] Long life battery upgrade or [PSU] external mains power adapter.

Free service: Provide our engineers with details of your monitoring requirements, we would be pleased to assist you in setting up your system ready for deployment.

RTR-500 Series Features

  • Remotely access your data over the internet for free.
  • Take control and ownership of your data using free issued offline analytical and archiving utilities.
  • Wide range of communication devices including the RTR500-DC handheld data collector for performing spot checks and analysis.
  • Robust and durable design.
  • Accurate and can be recalibrated.
  • User replaceable battery.
  • Optional GxP Validation service including installation.
  • Routine on-site calibration
Manufacturer

TandD

Parameter(s)

Voltage

Usage Type

Multiple Use

Connectivity

Wireless radio to USB [RTR-500]
Wireless radio to Ethernet LAN [RTR-500NW]
Wireless radio to Wireless LAN Wi-Fi [RTR-500AW]
Wireless radio to GSM 3G [RTR-500MBS]
Wireless radio to Handheld collector [RTR-500DC]

Sensor internal or external

External

Channels

1

Memory

16000 reading back-up memory

Sample rate

1 reading a second ~ 1 reading every hour

Range

0 ~ 22v

Accuracy

+/- 0.5mV
Contact our calibration department for advice on partnering with sensors and offset adjustment

Resolution

See specification sheet

Material

ABS Plastic with O-ring seal

Power

User replaceable battery
Mains with power supply adaptor

Battery Life

10 months - Standard battery
24 ~ 48 months - [L] Large battery

Dimensions

86mm x 47mm x 19mm - Standard battery
86mm x 47mm x 46.5mm - [L] Large battery

Environment

IP64 Splashproof
Sensor must be kept dry

Operating Conditions

-40°C ~ +80°C

Alarm

Email when using any RTR-500 base station
SMS text message when using RTR-500MBS
On-line when using TandD Webstorage-service
On PC when using Current readings utility
Audible/Visual beacon with optional attachment for base station

Features

Free remote internet access.
Free offline analytical and reporting utilities
Robust and durable design.
Accurate and can be recalibrated
User replaceable battery

Product Brochure
RTR500 Overview Brochure WPLSPDF40MB