PR140 pressure data logger
PR140 pressure data logger
PR140 pressure data logger
PR140 pressure data logger
PR140

PR140 Autoclave Pressure Data Logger

£750.00£810.00

This cost-effective pressure data logger is designed for use as an autoclave data logger, able to record data in high-temperature environments of up to +140°C. The MadgeTech PR140 data logger is recommend for use to validate autoclave sterilisation.

Product Description

Product Description

The MadgeTech PR140 is a rugged pressure data logger that measures 0 to 5 bar in harsh environments up to +140°C. Specifically designed for autoclave validation and sterilisation in the medical and pharmaceutical industries, the PR140 boasts features of much more expensive competitors.

PR140 features include:

  • Multi-use and a two-year battery life (readings every minute at 25°C)
  • Large memory of 32,700 readings
  • Cost-effective autoclave data logger

Manufactured from stainless steel and IP68 rated, this submersible data logger is durable and suitable for harsh environments. It benefits from a field replaceable battery.

Often used in conjunction with HiTemp140 temperature data loggers, the free Madgetech software enables users to analyse pressure alongside temperature, overlaying  graphical or tabular data. Lethality/sterilisation points F0 & A0 can automatically be calculated in the software. Data can be exported in Excel and PDF reports can be created for easy distribution of validation documentation to team members or compliance bodies.

Optional 21 CFR 11 compliant Madgetech secure software and validation workbook are available with this pressure data logger.

Required: IFC400 or IFC406 interface along with free issued MT4 software.

Calibration services available:

Optional pressure calibration of the standard points: 0 bar, 2.5 bar and 5 bar

Manufacturer

Madgetech

Parameter(s)

Pressure

Usage Type

Multi use

Connectivity

USB via IFC400 interface

Sensor internal or external

Internal

Channels

Single

Sensor type

Semiconductor Strain Gauge

Memory

32,700 readings

Sample rate

1 second to once every 24 hours

Range

0 ~ 5 Bar (0 ~ 72.5 PSIA)

Accuracy

±0.03 Bar (±0.435 PSI)
+20°C ~ +140°C

Resolution

0.1 mBar (0.0015 PSIA)

Material

Stainless Steel

Power

3.6v lithium

Battery Life

2 years typical (1 minute reading rate at 25°C)

Dimensions

58.2 mm x 25.4 mm diameter

Environment

-20°C to +140°C , 0%RH to 100%RH
Note: The PR140 may be used above +60°C for up to 8 hours, per 24 hour period

Operating Conditions

-20°C to +140°C , 0%RH to 100%RH
Note: The PR140 may be used above +60°C for up to 8 hours, per 24 hour period

Features

Cost effective autoclave pressure data logger

Product Brochure
PR140 Data Sheet WPLS PDF 691 KB
Instruction Manual
PR140 Information Card WPLS PDF 335 KB

Product Description

Product Description

The MadgeTech PR140 is a rugged pressure data logger that measures 0 to 5 bar in harsh environments up to +140°C. Specifically designed for autoclave validation and sterilisation in the medical and pharmaceutical industries, the PR140 boasts features of much more expensive competitors.

PR140 features include:

  • Multi-use and a two-year battery life (readings every minute at 25°C)
  • Large memory of 32,700 readings
  • Cost-effective autoclave data logger

Manufactured from stainless steel and IP68 rated, this submersible data logger is durable and suitable for harsh environments. It benefits from a field replaceable battery.

Often used in conjunction with HiTemp140 temperature data loggers, the free Madgetech software enables users to analyse pressure alongside temperature, overlaying  graphical or tabular data. Lethality/sterilisation points F0 & A0 can automatically be calculated in the software. Data can be exported in Excel and PDF reports can be created for easy distribution of validation documentation to team members or compliance bodies.

Optional 21 CFR 11 compliant Madgetech secure software and validation workbook are available with this pressure data logger.

Required: IFC400 or IFC406 interface along with free issued MT4 software.

Calibration services available:

Optional pressure calibration of the standard points: 0 bar, 2.5 bar and 5 bar

Manufacturer

Madgetech

Parameter(s)

Pressure

Usage Type

Multi use

Connectivity

USB via IFC400 interface

Sensor internal or external

Internal

Channels

Single

Sensor type

Semiconductor Strain Gauge

Memory

32,700 readings

Sample rate

1 second to once every 24 hours

Range

0 ~ 5 Bar (0 ~ 72.5 PSIA)

Accuracy

±0.03 Bar (±0.435 PSI)
+20°C ~ +140°C

Resolution

0.1 mBar (0.0015 PSIA)

Material

Stainless Steel

Power

3.6v lithium

Battery Life

2 years typical (1 minute reading rate at 25°C)

Dimensions

58.2 mm x 25.4 mm diameter

Environment

-20°C to +140°C , 0%RH to 100%RH
Note: The PR140 may be used above +60°C for up to 8 hours, per 24 hour period

Operating Conditions

-20°C to +140°C , 0%RH to 100%RH
Note: The PR140 may be used above +60°C for up to 8 hours, per 24 hour period

Features

Cost effective autoclave pressure data logger

Product Brochure
PR140 Data Sheet WPLS PDF 691 KB
Instruction Manual
PR140 Information Card WPLS PDF 335 KB