TitanS8TouchScreenPortableUniversalDataLogger

By MadgeTech Data Loggers
£882.00

Overview

The TitanS8 touch screen data logger by MadgeTech has 8 channels, is portable and combines industrial toughness with scientific accuracy. The Titan S8 can be used as a standalone data logger due to its versatility and ability to measure current, voltage, temperature and pulse in real time.

Information

Product Description

The MadgeTech Titan S8 touch screen data logger is a portable, multi-use industrial data logger with eight probe channels and a user-friendly touchscreen interface. The Titan S8 is a complete all in one solution, unlike many other data loggers, it does not require a PC or downloaded software to work. The touch screen allows the user to see their historic data at the touch of a button, including:

  • Display rotation
  • Real time data visualization
  • On screen alerts
  • Wiring diagram
  • On screen keyboard
  • Built in troubleshooting
  • Language translation

This versatile, portable data logger supports thermocouple, RTD or thermistor temperature probes to measure current, voltage, temperature and pulse in real time. This adaptability and power make Titan S8 the perfect companion for any industrial engineer, quality assurance professional, compliance officer or automotive technician.

The technology  used in the Titan S8 is comprised of:

  • 8 Input channels
  • USB data download
  • 1GB of internet memory to store up to 180,000,000 readings
  • Engineering units
  • No required software
  • Rechargeable battery

Specifications

Channels

8

Power

Rechargeable battery: 10 hours continuous use
Mains power

Dimensions

168.9mm x 111.8 x 35.8mm
5" touch screen

Protection

Integral TPE protective boot
IP20

Recording rate

• 4 KHz ~ 10Hz - Single channel mV/V/mA
• 4 Hz
• 1 Second
• 2 Seconds
• 5 Seconds
• 10 Seconds
• 15 Seconds
• 30 Seconds
• 1 Minute
• 2 Minutes
• 5 Minutes
• 10 Minutes
• 15 Minutes
• 30 Minutes
• 1 Hour
• 2 Hours
• 5 Hours
• 10 Hours
• 12 Hours
• 24 Hours

Temperature rating

0~50°C

Humidity rating

0~95%rH

Current measuring range

Range:-5mA~50mA
Resolution: 0.0001mA
Accuracy: +/-0.024mA
Input impedance: 30 Ohm

mV measuring range

Range: -100mV ~ 2450mV
Resolution: 0.0001mV
Accuracy: +/- 0.1mV (0~100mV)
Input impedance: 1 GOhm
Maximum voltage: 3V

Voltage measuring range

Range: -0.5V~ 12V
Resolution: 0.0001V
Accuracy: +/- 0.01V (-0.5V~12V)
Input impedance: 1 GOhm
Maximum voltage: 25V

PT100 Temperature measuring range and specification

3 wire
Range: -25°C~+850°C
Resolution: 0.01°C
Accuracy: 0.1°C

Frequency/Pulse measuring range and specification

Maximum count: 4,000,000,000
Maximum frequency: 25KHz
Input signal: 0~12V
Impedance: 58 KOhm

Thermcouple type and range

Type J -200°C to +760 °C
Type K -270 °C to +1370 °C
Type T -270 °C to +400 °C
Type E -270 °C to +980 °C
Type R -50 °C to +1760 °C
Type S -50 °C to +1760 °C
Type B +50 °C to +1820 °C
Type N -270 °C to +1300 °C