RFCurrent2000A wireless current data logger
RFCurrent2000A wireless current data logger
RFCurrent2000A wireless current data logger
RFCurrent2000A wireless current data logger
RFCurrent2000A
RFCurrent2000A wireless current data logger
RFCurrent2000A wireless current data logger
RFCurrent2000A wireless current data logger
RFCurrent2000A wireless current data logger
RFCurrent2000A

RFCurrent2000A USB and Wireless 4~20mA Data Logger

£215.00

Current, USB or wireless radio data logger.

QuantityPriceYou Save
5+£202.106%
11+£197.808%
30+£184.9014%
50+£182.7515%
100+£176.3018%
1+£2150%

Product Description

The RFCurrent2000A is a compact data logger for monitoring and recording data delivered by sensors with a 4-20mA current output.

it is either battery or mains powered so it can be deployed as a handheld, situated on a desk or mounted to a wall using the innovative supplied bracket. View real-time data on the LCD screen, trigger local audible/visual alarms and connect to a USB computer for periodic analysis. If at a later date you want to link the data loggers up to deliver real-time alarms and data then we need to check signals and recommend the required number of RFC1000 repeater.

Ideally suited to clients looking for a quality analogue 4 ~ 20mA data logger that could be networked, should manually collecting data loggers become time consuming.

Hardware Features

  • Direct current connection via terminal block.
  • USB and Wireless connectivity .
  • Current data logger
  • Email and audible alarms.
  • LCD display.
  • Battery or optional mains powered.
  • Cloud services compatibility.

MT4 standard software Features

  • Engineering Units – Scale your current data against engineered parameters like PSI
  • Graph – Multi plot, multi parameter with zoom functions linked to statistics
  • Tabular – Time versus parameter data presented in a printable table
  • Reports – Powerful module which collates data collected from multiple devices
  • Workflows – Automate routine tasks such as download, configuration, reporting and saving collected data
  • Time markers and value lines –  Assist in organising data into stages and clearly presenting pass/fail limits
  • Advanced statistics – Sterilisation, MKT, time until threshold, mathematical channels and more..
  • .CSV export – Single button export results in generation of a fully formatted spreadsheet.
  • Annotation – Apply cooling flags and markers on your results
  • Configuration – user definable with multiple data logging batch programming facility
  • Secure archive – Automatically save critical data within a secure database

Supplied with: Sensors, battery, mounting/stand bracket , MT4 software and USB cable.

Optional: 

  • MadgeTech Secure SVP for FDA 21 CFR Part 11 Compliance supported with GxP IQ/OQ/PQ validation documentation
  • MadgeTech Relay and Cloud services for real-time and alarm management on any internet enabled device.
  • Mains power adapter
  • Also available in 160mA and 3A measurement ranges
Manufacturer

Madgetech

Parameter(s)

Current

Usage Type

Multi use

Connectivity

USB and wireless radio

Sensor internal or external

Internal

Channels

1 channel

Memory

32,256 readings per channel

Sample rate

1 reading every second ~ 1 reading every 24 hours

Range

-2 mA to +30 mA
-160 mA to +160 mA
-3 A to +3 A

IP Rating

IP22

Material

ABS Plastic

Power

Battery 9v Lithium or mains power adaptor

Battery Life

4 years typical at a 15 minute reading rate

Dimensions

20 mA & 3 A: 3.19 in x 3.5 in x 0.95 in
(80.9 mm x 88.9 mm x 24.1 mm) - Data logger only
160 mA: 3.17 in x 3.5 in x 0.95 in
(80.5 mm x 88.9 mm x 24.1 mm) - Data logger only

Environment

-20 °C to ~ 60 °C, 0 %RH to 95 %RH non-condensing

Alarm

Audible Alarm (built in), emails

Features

USB and Wireless , email & audible alarms, , LCD display, battery or mains powered

Product Brochure
RFcurrent2000A Datasheet WPLSPDF1 MB
Instruction Manual
RFcurrent2000A User Guide WPLSPDF523 KB
Software
MadgeTech SoftwareZIP25MB

Product Description

The RFCurrent2000A is a compact data logger for monitoring and recording data delivered by sensors with a 4-20mA current output.

it is either battery or mains powered so it can be deployed as a handheld, situated on a desk or mounted to a wall using the innovative supplied bracket. View real-time data on the LCD screen, trigger local audible/visual alarms and connect to a USB computer for periodic analysis. If at a later date you want to link the data loggers up to deliver real-time alarms and data then we need to check signals and recommend the required number of RFC1000 repeater.

Ideally suited to clients looking for a quality analogue 4 ~ 20mA data logger that could be networked, should manually collecting data loggers become time consuming.

Hardware Features

  • Direct current connection via terminal block.
  • USB and Wireless connectivity .
  • Current data logger
  • Email and audible alarms.
  • LCD display.
  • Battery or optional mains powered.
  • Cloud services compatibility.

MT4 standard software Features

  • Engineering Units – Scale your current data against engineered parameters like PSI
  • Graph – Multi plot, multi parameter with zoom functions linked to statistics
  • Tabular – Time versus parameter data presented in a printable table
  • Reports – Powerful module which collates data collected from multiple devices
  • Workflows – Automate routine tasks such as download, configuration, reporting and saving collected data
  • Time markers and value lines –  Assist in organising data into stages and clearly presenting pass/fail limits
  • Advanced statistics – Sterilisation, MKT, time until threshold, mathematical channels and more..
  • .CSV export – Single button export results in generation of a fully formatted spreadsheet.
  • Annotation – Apply cooling flags and markers on your results
  • Configuration – user definable with multiple data logging batch programming facility
  • Secure archive – Automatically save critical data within a secure database

Supplied with: Sensors, battery, mounting/stand bracket , MT4 software and USB cable.

Optional: 

  • MadgeTech Secure SVP for FDA 21 CFR Part 11 Compliance supported with GxP IQ/OQ/PQ validation documentation
  • MadgeTech Relay and Cloud services for real-time and alarm management on any internet enabled device.
  • Mains power adapter
  • Also available in 160mA and 3A measurement ranges
Manufacturer

Madgetech

Parameter(s)

Current

Usage Type

Multi use

Connectivity

USB and wireless radio

Sensor internal or external

Internal

Channels

1 channel

Memory

32,256 readings per channel

Sample rate

1 reading every second ~ 1 reading every 24 hours

Range

-2 mA to +30 mA
-160 mA to +160 mA
-3 A to +3 A

IP Rating

IP22

Material

ABS Plastic

Power

Battery 9v Lithium or mains power adaptor

Battery Life

4 years typical at a 15 minute reading rate

Dimensions

20 mA & 3 A: 3.19 in x 3.5 in x 0.95 in
(80.9 mm x 88.9 mm x 24.1 mm) - Data logger only
160 mA: 3.17 in x 3.5 in x 0.95 in
(80.5 mm x 88.9 mm x 24.1 mm) - Data logger only

Environment

-20 °C to ~ 60 °C, 0 %RH to 95 %RH non-condensing

Alarm

Audible Alarm (built in), emails

Features

USB and Wireless , email & audible alarms, , LCD display, battery or mains powered

Product Brochure
RFcurrent2000A Datasheet WPLSPDF1 MB
Instruction Manual
RFcurrent2000A User Guide WPLSPDF523 KB
Software
MadgeTech SoftwareZIP25MB

Similar Products